Ductless - Outdoor unit, 23.8 38MGR 2.5, Multiple Zone
$0.00
/ EACH
Restricted:
WarehouseRestricted::1001, WarehouseRestricted::1003, WarehouseRestricted::1005, WarehouseRestricted::1007, WarehouseRestricted::1009, WarehouseRestricted::1011, WarehouseRestricted::1013, WarehouseRestricted::1015, WarehouseRestricted::1017, WarehouseRestricted::1019, WarehouseRestricted::1021, WarehouseRestricted::1023, WarehouseRestricted::1025, WarehouseRestricted::1027, WarehouseRestricted::1029, WarehouseRestricted::1031, WarehouseRestricted::1033, WarehouseRestricted::1035, WarehouseRestricted::1037, WarehouseRestricted::1039, WarehouseRestricted::1041, WarehouseRestricted::1043, WarehouseRestricted::1045, WarehouseRestricted::1047, WarehouseRestricted::1049, WarehouseRestricted::1051, WarehouseRestricted::1053, WarehouseRestricted::1055, WarehouseRestricted::1057, WarehouseRestricted::1059, WarehouseRestricted::1061, WarehouseRestricted::1063, WarehouseRestricted::1065, WarehouseRestricted::1067, WarehouseRestricted::1069, WarehouseRestricted::1071, WarehouseRestricted::1073, WarehouseRestricted::1076, WarehouseRestricted::1077, WarehouseRestricted::1078, WarehouseRestricted::1079, WarehouseRestricted::1080, WarehouseRestricted::1105, WarehouseRestricted::1109, WarehouseRestricted::1111
:
Each
:
Trading Goods (ZAW1)
:
Technical Defect
Brand:
Carrier
Compressor:
Rotary Inverter
Equipment Type:
Ductless Split System
Manufacturer:
Carrier
Nominal Capacity (Ton):
2.5 Ton
Nominal Seer:
23
Refrigerant:
R-410A
Seer:
23.8
Tonnage:
2.5
Cfm:
2130
Coil Fins Per Inch:
20°
Combination Cooling Capacity Max:
42305
Compressor Model:
ATF310D43UMT
Cooling Operating Range:
-13~122
Eer:
12.5
Frequency:
60
Lift Od Below Id:
45-49
Liquid Line Size:
1/4*4
Nominal Sound:
62
Phase:
Single
Tonnage:
2.5
Coil Number Of Circuits:
CHARLES S CRAMER
Combination Cooling Capacity Min:
6275
Compressor Type:
Rotary Inverter
Cooling Capacity Max:
13000
Drop Od Above Id:
45-49
Heating Operating Range:
-22~86
Hspf:
ALFA LAVAL INC
Metering Device:
EEV
Seer:
23.8
Coil Number Of Rows:
Editor
Combination Cooling Rated Capacity:
30,000
Cooling Capacity Min:
4800
Mca:
30°
Refrigerant Weight:
6.61
Combination Cop 17F:
2.65
Cop:
Editor
Face Area:
8.78
Combination Cop 47F:
3.7
Max Number Of Zones:
Carrier
Maximum Piping Length:
263 ft.
Minimum Circuit:
30°
Minimum Piping Length:
10 ft.
Oil Charge:
35.27
Size:
30°
Suction Line Size:
1/2 *1+ 3/8*3
Combination Cop 5F:
1.99
Mocp Fuse Rating:
45°
Oil Type:
ESTER OIL VG74
Total Piping Length:
263
Combination Eer:
11.25
Rated Current:
19°
Combination Heating Capacity Max:
39990
Combination Heating Capacity Min:
8060
Combination Heating Max Capacity 13F:
23390
Combination Heating Max Capacity 5F:
28615
Heating Max Capacity 5F:
29230
Combination Heating Rated Capacity 17F:
20200
Combination Heating Rated Capacity 47F:
29000
Combination Hspf:
ALFA LAVAL INC
Nominal Heating Capacity:
6200
Combination Seer:
22.4
Combination Tonnage:
2.5
Ducted Cooling Capacity Max:
38510
Ducted Cooling Capacity Min:
8030
Ducted Cooling Rated Capacity:
30,000
Ducted Cop 17F:
2.52
Ducted Cop 47F:
3.6
Ducted Cop 5F:
1.98
Ducted Eer:
ALFA LAVAL INC
Ducted Heating Capacity Max:
42660
Ducted Heating Capacity Min:
6200
Ducted Heating Max Capacity 13F:
22260
Ducted Heating Max Capacity 5F:
28000
Ducted Heating Rated Capacity 17F:
23000
Ducted Heating Rated Capacity 47F:
30,000
Ducted Hspf:
ALFA LAVAL INC
Ducted Seer:
21°
Ducted Tonnage:
2.5
Non Ducted Cooling Capacity Max:
41470
Non Ducted Cooling Capacity Min:
8090
Non Ducted Cooling Rated Capacity:
30,000
Non Ducted Cop 17F:
2.78
Non Ducted Cop 47F:
3.8
Non Ducted Cop 5F:
Editor
Non Ducted Eer:
12.5
Non Ducted Heating Capacity Max:
41950
Non Ducted Heating Capacity Min:
6350
Non Ducted Heating Max Capacity 13F:
24520
Non Ducted Heating Rated Capacity 17F:
17400
Non Ducted Heating Rated Capacity 47F:
28000
Non Ducted Hspf:
ALFA LAVAL INC
Non Ducted Seer:
23.8
Non Ducted Tonnage:
2.5