Heat Pump 18 SEER 3 Ton ( 208/230 )

25VNA837A003
$0.00 / EACH
  • : Carrier
  • : Trading Goods (ZAW1)
  • : 03 - Use
  • : Each
  • : Pound(LB)
  • : Standard Item (NORM)
  • Nominal Seer: 18
  • Nominal Voltage: 208/230
  • Refrigerant: R-410A
  • Accumulator: True
  • Cfm Nominal: 3800
  • Coastal: False
  • Compressor Rla: 19.6
  • Condenser Motor Fan Speeds: Variable - Speed
  • Configuration: Vertical
  • Max Sound Level: 71
  • Maximum Cop: 3.5
  • Coil Guard Type: Louver
  • Communicating: True
  • Condenser Motor Hp: 1/3
  • Frequency: 60
  • High Pressure Switch: True
  • Maximum Cooling Capacity: 33600
  • Maximum Eer: 13
  • Min Sound Level: 71
  • Sound Blanket: True
  • Condenser Motor Nominal Rpm: 3
  • Inverter: True
  • Liquid Line Fitting: Sweat
  • Maximum Heat Efficiency Hspf: 11
  • Maximum Heating Capacity: HONEYWELL INC
  • Outdoor Fins Per Inch: 20"
  • Compressor Type: Rotary
  • Condenser Motor Type: Brushless DC
  • Liquid Line Size: 3/8
  • Maximum Seer: 15-19
  • Minimum Cooling Capacity: 31400
  • Outdoor Number Of Rows: 1
  • Fan Diameter: 24'
  • Low Pressure Switch: False
  • Maximum Circuit Breaker: 35-39
  • Minimum Eer: 10
  • Minimum Heating Capacity: 40000
  • Maximum Piping Length: 1
  • Maximum Voltage: 253
  • Minimum Heat Efficiency Hspf: 8.2
  • Nominal Cooling Capacity: 31400
  • Number Of Fan Blades: 3"
  • Mca: 26°
  • Metering Device Cooling: TXV
  • Minimum Seer: 1/4
  • Outdoor Fan Motor Fla: 1.32
  • Tonnage: 3"
  • Metering Device Heating: EXV
  • Minimum Voltage: 197
  • Nominal Cop: 2.92
  • Minimum Heating Ambient Temperature: 35-39
  • Nominal Eer: 10
  • Phase: Single
  • Nominal Heat Efficiency Hspf: 8.2
  • Suction Line Fitting: Sweat
  • Nominal Seer: 18"
  • Suction Line Size: 1 1/8
Overview

The Infinity 18VS heat pump is different in a lot of ways. It offers variable-speed compression that can step down in 5 stages to as low as 25% of its capacity. That's huge from a comfort perspective. The ability to run in lower speeds most of the time makes it quieter and more adept at removing humidity in the summer. It's also significantly better than a 2-stage unit at keeping temperatures even. Plus, those lower speeds are the sweet spot for the unit's best efficiency levels and for getting the most benefit out of other systems you might have like an air purifier because of more constant air flow through the system.

And, it's seldom you can upgrade your system a component at a time. Most often, the leap to higher efficiency and better comfort via a communicating system for that home you love, can mean you have to deal with the cost of a whole system even though only your outdoor cooling unit has called it quits. The Infinity 18VS could change that for you. Your Carrier® expert can help you determine if it can work with your existing indoor unit so you can upgrade in steps.

Features

STANDARD FEATURES

  • Up to 19 SEER cooling efficiency
  • Up to 11 HSPF heating efficiency
  • Sound: as low as 55 decibels1
  • Optimal humidity and temperature control when managed by the Inifinty Touch control
  • Variable, 5-stage compressor operation for ultimate comfort and quiet
  • Compressor sound blanket and Silencer System II design
  • Filter drier system protection from moisture and contaminants
  • Ideal Defrost heating operation with Infinity control
  • WeatherArmor Ultra protection
  • Non-ozone depleting Puron® refrigerant
  • 10-year parts limited warranty2

OPTIONAL FEATURES

  • Optional labor warranty available3


1 Quietest size within each model group during most common cooling operating condition.

2 Ask your Carrier® dealer for details.

3 To the original owner, when product is used in a residence, a 5-year seacoast corrosion parts limited warranty. See warranty certificate for complete details.

Specifications

EFFICIENCY

  • Up to 19 SEER
  • Up to 12.5 EER
  • Up to 11 HSPF
  • Select sizes meet ENERGY STAR® qualifications1

PERFORMANCE

  • Optimal summer dehumidification when managed by the Infinity Touch control
  • Variable, 5-stage compressor operation as low as 25% capacity up to 100%
  • Excellent cold weather performance with better heating capacity than 2-stage units
  • Hybrid Heat® system compatible
  • Sound: as low as 55 decibels2
  • Soft start and smooth ramp up to higher operating speeds

TECHNOLOGY

  • Integrated inverter control drives compressor and fan motor
  • Designed for highest efficiencies when part of a communicating Infinity system but compatible with 2-stage thermostats and suitable non-communicating indoor products for 2-stage operation
  • System protecting high and low pressure switches
  • Sound reduction: pressure equalizer valve, soft start, compressor sound blanket, Silencer System II design and forward swept fan blades
  • Filter drier
  • Infinity level advanced diagnostic intelligence
  • Recommended control: Infinity Touch control

CAPACITIES

  • 2-4 ton

REQUIREMENTS

  • 208-230 V

AESTHETICS

  • Heavy-gauge, galvanized steel construction
  • Baked-on, durable powder coat paint
  • Steel, louvered coil guard


1 Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.

2 Quietest size within each model group during most common operating condition.

QTY