Aprilaire Model 8145NC Ventilator with Powered Damper and Filter

RP-MODEL 8145NC
$0.00 / EACH
  • Availability: WarehouseAvailability::1003, WarehouseAvailability::1009, WarehouseAvailability::1069
  • Restricted: WarehouseRestricted::1001, WarehouseRestricted::1003, WarehouseRestricted::1005, WarehouseRestricted::1007, WarehouseRestricted::1009, WarehouseRestricted::1011, WarehouseRestricted::1013, WarehouseRestricted::1015, WarehouseRestricted::1017, WarehouseRestricted::1019, WarehouseRestricted::1021, WarehouseRestricted::1023, WarehouseRestricted::1025, WarehouseRestricted::1027, WarehouseRestricted::1029, WarehouseRestricted::1031, WarehouseRestricted::1033, WarehouseRestricted::1035, WarehouseRestricted::1037, WarehouseRestricted::1039, WarehouseRestricted::1041, WarehouseRestricted::1043, WarehouseRestricted::1045, WarehouseRestricted::1047, WarehouseRestricted::1049, WarehouseRestricted::1051, WarehouseRestricted::1053, WarehouseRestricted::1055, WarehouseRestricted::1057, WarehouseRestricted::1059, WarehouseRestricted::1061, WarehouseRestricted::1063, WarehouseRestricted::1065, WarehouseRestricted::1067, WarehouseRestricted::1069, WarehouseRestricted::1071, WarehouseRestricted::1073, WarehouseRestricted::1076, WarehouseRestricted::1077, WarehouseRestricted::1078, WarehouseRestricted::1079, WarehouseRestricted::1080, WarehouseRestricted::1105, WarehouseRestricted::1109, WarehouseRestricted::1111, WarehouseRestricted::1113
  • : Each
  • : Pound(LB)
  • : Trading Goods (ZAW1)
  • : Technical Defect
  • : Standard Item (NORM)
  • Auto Enrichment Status: Ready
  • Manufacturer: Research Products
The Model 8145NC has no integrated control so the ventilator can be hardwired to the HVAC system and controlled from within the living space.

Motor 55 watts; 0.5 amps (FLA) @ 115v/LPH/60Hz

Control provides the capability to adjust the high/low outdoor temperature limits and indoor RH limits

6-foot power cord with a standard 5-15P plug provided with unit

24-volt wiring to HVAC system. Furnace or air handler does not require an EC motor to qualify to meet the ventilation efficiency requirements of Energy Star for homes, or 2012 - 2018 International Energy Code

Integrated powered damper and removable, washable MERV 6 filter. Replacement MERV 13 filter available.

For indoor use only; Installation temperature up to 140°F

Duct collars accept 6" duct

ETL listed When properly installed and set, it will meet the following mechanical ventilation requirements:**

•ASHRAE Standard 62.2
•Energy Star for Homes
•EPA Indoor airPLUS
•2018/2015/2012 International Residential Code (IRC)
•2018/2015/2012 International Energy Conservation Code (IECC)
•California Energy Commission Title 24

*Pat. No. 9,874,366. Applies to all controls listed below.
**8145NC compliance is subject to the functionality of the external control. To assure compliance, use an 8910, 8910W, 8920W, 8620 or 8620W thermostat or 8120X ventilation controller
QTY