Availability:
WarehouseAvailability::1035
-
Restricted:
WarehouseRestricted::1001, WarehouseRestricted::1003, WarehouseRestricted::1005, WarehouseRestricted::1007, WarehouseRestricted::1009, WarehouseRestricted::1011, WarehouseRestricted::1013, WarehouseRestricted::1015, WarehouseRestricted::1017, WarehouseRestricted::1019, WarehouseRestricted::1021, WarehouseRestricted::1023, WarehouseRestricted::1025, WarehouseRestricted::1027, WarehouseRestricted::1029, WarehouseRestricted::1031, WarehouseRestricted::1033, WarehouseRestricted::1035, WarehouseRestricted::1037, WarehouseRestricted::1039, WarehouseRestricted::1041, WarehouseRestricted::1043, WarehouseRestricted::1045, WarehouseRestricted::1047, WarehouseRestricted::1049, WarehouseRestricted::1051, WarehouseRestricted::1053, WarehouseRestricted::1055, WarehouseRestricted::1057, WarehouseRestricted::1059, WarehouseRestricted::1061, WarehouseRestricted::1063, WarehouseRestricted::1065, WarehouseRestricted::1067, WarehouseRestricted::1069, WarehouseRestricted::1071, WarehouseRestricted::1073, WarehouseRestricted::1076, WarehouseRestricted::1077, WarehouseRestricted::1078, WarehouseRestricted::1079, WarehouseRestricted::1080, WarehouseRestricted::1105, WarehouseRestricted::1109, WarehouseRestricted::1111, WarehouseRestricted::1113
-
:
Each
-
:
Pound(LB)
-
:
Trading Goods (ZAW1)
-
:
Technical Defect
-
:
Standard Item (NORM)
-
Auto Enrichment Status:
Ready
-
Manufacturer:
Research Products
Model 8145A improves indoor air quality by bringing the appropriate amount of outdoor air into tight homes and complies with ASHRAE Standard 62.2.*
Integrated control optimizes energy savings by locking out ventilation during hottest/coldest times of the day.*†
Motor 55 watts; 0.5 amps (FLA) @ 115v/LPH/60Hz
6-foot power cord with a standard 5-15P plug provided with unit
24-volt wiring to HVAC system. Furnace or air handler does not require an EC motor to qualify to meet the ventilation efficiencyrequirementsofEnergyStarforhomes,or2012-2018 International Energy Code
Integrated powered damper and removable, washable MERV 6 filter. Replacement MERV13 filter
available.
For indoor use only; Installation temperature up to 140°F
Duct collars accept 6” duct
ETL listed
When properly installed and set, it will meet the following mechanical ventilation requirements:**
• ASHRAE Standard 62.2
• Energy Star for Homes
• EPA Indoor airPLUS
• 2018/2015/2012 International Residential Code (IRC)
• 2018/2015/2012 International Energy Conservation Code (IECC)
• California Energy Commission Title 24
* Model 8145A only.
** 8145NC compliance is subject to the functionality of the external control. To assure compliance, use an 8910, 8910W, 8920W, 8620 or 8620W thermostat 8120A or 8120X ventilation controller.
*** Measured across ventilator.
† Pat. No. 9,874,366. Applies to all controls listed above.