Electric/Electric 12.5 Ton Packaged Rooftop Unit

50FC-M14A2A5-0A0A0
$0.00 / EACH
  • : Carrier
  • : Trading Goods (ZAW1)
  • : 03 - Use
  • : Each
  • : Pound(LB)
  • : Standard Item (NORM)
  • Auto Enrichment Status: Ready

Electric Heat / Electric Cooling & Cooling Only with Ecoblue™ Technology

3 to 27.5 Nominal Tons

Exclusive, new EcoBlue™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The industry’s first beltless direct-drive vane axial fan for rooftop units* is just one of many technological advances that prove that not all rooftop units are created equal. Other enhancements include a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors and more – all available on this multiefficiency offering.

*Available on select models

Features

Performance Features

  • Meets and exceeds ASHRAE 90.1 energy efficiency levels
  • New unit control board with intuitive quick fan speed adjustment
  • New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
  • Single-stage cooling capacity 04-06 models, two-stage on 07 models
  • SEERs up to 14.0, IEER of 15.2
  • Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit
  • Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Maintenance Features

  • New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Optional hinged access panels also available
  • NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as prior Carrier models for that original fit; reduces installation costs and time
  • Field convertible from vertical to horizontal airflow configuration
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point electric, and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated direct-drive ECM evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection

Standard Limited Warranty

  • 5 years electric heaters
  • 5 years parts only compressor
  • 3 year SystemVu™ controller
  • One year parts only on all other parts
  • Additional extended warranty packages available
Options

Factory-Installed Options

  • Temperature Sensing EconoMi$er with relief
  • Enthalpy Sensing EconoMi$er with relief
  • Humidi-MiZer® Adaptive Dehumidification System
  • Return Air Smoke Detector
  • Supply Air Smoke Detector
  • CO2 Sensor
  • Condensate Overflow Protection
  • Multiple Static Fan Capabilities
  • Phase Monitor/Protection
  • Thru-The-Base Utility Connections
  • Louvered Hail Guards
  • Non-Fused Disconnect Switch
  • MERV-8 Return Air Filters
  • Hinged Access Panels
  • Unpowered Convenience Outlet
  • Powered Convenience Outlet
  • Coated Coils:
    • Pre-Coat
    • E-Coat
    • Copper/Copper
  • Electrical Mechanical Controls
  • SystemVu™ Integrated Communicating Controls
  • RTU-Open Communicating Controls
  • Extended Warranty Protection Plans
  • Financing Available
Physical Data

Electric Heat/Electric Cooling & Cooling Only Models (50FC)

Nominal Cooling Ton SizeCooling StagesAHRI Efficiency (SEER) IEERDimensions (in) LxWxHElectrical Heat Nominal kW RangeApprox. Unit Weight (lbs)
31(14.0)74 x 47 x 334.0 to 15.0437
41(14.0)74 x 47 x 334.0 to 21.0498
51(14.0)74 x 47 x 336.5 to 24.0511
6215.274 x 47 x 416.5 to 24.0562

AHRI = Air-Conditioning, Heating & Refrigeration Institute

ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.

IEER = Integrated Energy Efficiency Ratio

SEER = Seasonal Energy Efficiency Ratio

NOTES

1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate.


2. Ratings are based on:


» Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp.


3. All 50FC units comply with ASHRAE 90.1-2010 Energy Standard for minimum SEER and EER requirements.


4. 50FC units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes or visit the following website: http://bcap-energy.org

QTY