Heat Pump 5 Ton Packaged Rooftop Unit

50FCQA06A2A5-0A0A0
$0.00 / EACH
  • : Carrier
  • : Trading Goods (ZAW1)
  • : 03 - Use
  • : Each
  • : Pound(LB)
  • : Standard Item (NORM)
  • Coil Type: RTPF
  • Coil Type: RTPF
  • Fan Diameter: 16.6
  • Fan Diameter: 23°
  • Fla: 1.5
  • Oa Inlet Screen Quantity: 1
  • Condensate Drain Connection Size: 3/4
  • Fan Quantity: 1
  • Fpi: 18"
  • Lra: 110
  • Motor Drive Type: Direct
  • Oa Inlet Screen Size: 20x24x1
  • Compressor Type: Scroll
  • Fan Type: Vane Axial
  • Fpi: 15
  • Motor Hp: 1/4
  • Ra Filter Quantity: 4"
  • Rla: 1/6
  • Rows: 2
  • High Pressure Reset: 505
  • Max Cont Bhp: 1.44
  • Motor Quantity: 1
  • Ra Filter Size: 16x16x2
  • Rows: 4"
  • Total Face Area: 18.8
  • High Pressure Trip: 630
  • Motor Drive Type: Direct
  • Motor Rpm: 1100
  • Total Face Area: 7.3
  • Tube Diameter: 5/16
  • Low Pressure Reset: 117
  • Tube Diameter: 3/8
  • Tube Material/Fin Material: Cu/Al
  • Low Pressure Trip: 50-54
  • Motor Quantity: 1
  • Tube Material/Fin Material: Cu/Al
  • Metering Device: Acutrol
  • Rpm Maximum: 2390
  • Number Of Circuit: 1
  • Rpm Minimum: 239
  • Number Of Compressor: 1
  • Refrigerant Type: R-410A

Heat Pump Units with Puron® (R-410A) Refrigerant

3 to 25 Nominal Tons

Patented, new EcoBlue™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The industry’s first beltless direct-drive vane axial fan for rooftop units is just one of many technological advances that prove that not all rooftop units are created equal. Other enhancements include a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors and more – all available on this multi efficiency offering.

Features

Performance Features

  • New unit control board with intuitive quick fan speed adjustment
  • New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
  • Single-stage cooling capacity 04-06 models, two-stage on 07 models
  • SEERs to 14.3, IEER of 15.0
  • HSPF to 8.2 and COP’s to 3.6
  • Standard Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C), lower temperature operation possible with low ambient kits
  • Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Proven high performance round copper tube and aluminum fin coil designs
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
  • 04 to 06 models use fixed refrigerant metering device and 07 models use a TXV

Maintenance Features

  • New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Optional hinged access panels also available
  • NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as prior Carrier models for that original fit; reduces installation costs and time
  • Field convertible from vertical to horizontal airflow configuration
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point electrical and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated direct-drive ECM evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Precisely sizes suction line accumulator
  • Proven Time/Temperature defrost logo and control board

Standard Limited Warranty

  • 5 years electric heaters
  • 5 years parts only compressor
  • 3 year SystemVu™ controller
  • One year parts only on all other parts
  • Additional extended warranty packages available
Options

Factory-Installed Options

  • Temperature Sensing EconoMi$er with built-in relief
  • Enthalpy Sensing EconoMi$er with built-in relief
  • Multiple Electric Heat Sizes & Voltages
  • Return Air Smoke Detector
  • Supply Air Smoke Detector
  • CO2 Sensor
  • Condensate Overflow Protection
  • Multiple Static Fan Capabilities
  • Phase Monitor/Protection
  • Thru-The-Base Utility Connections
  • Louvered Hail Guards
  • Non-Fused Disconnect Switch
  • MERV-8 Return Air Filters
  • Hinged Access Panels
  • Unpowered Convenience Outlet
  • Powered Convenience Outlet
  • Coated Coils:
    • Pre-Coat
    • E-Coat
    • Copper/Copper
  • Electrical Mechanical Controls
  • Intelligent SystemVu™ Integrated Communicating Controls
    • Large full text – multi line display
    • USB Flash Port for data transfer
    • Built in i-Vu®, CCN and BACnet®
    • Refrigerant pressure from display
    • Quick LED Status – Run, Alert, Fault
    • Conventional stat or sensor capabilities
    • Historical component runtime and starts
    • Supply Air Tempering
    • Equipment / System Touch Compatibility
    • Demand Limiting and ZS Sensor Compatibility
  • RTU-Open Communicating Controls
  • Extended Warranty Protection Plans
  • Financing Available
Physical Data

Heat Pump Models (50FCQ)

Nominal Cooling Ton SizeCooling StagesAHRI Efficiency (SEER) IEERDimensions (in) LxWxHAt 47°FAt 17°FApprox. Unit Weight (lbs)
Heating Capacity (Btuh)HSPF COPHeating Capacity (Btuh)HSPF COP
31(14.3)74 x 47 x 3334000(8.2)17000n/a467
41(14.3)74 x 47 x 3346600(8.2)23600n/a473
51(14.3)74 x 47 x 41

56500(8.2)30000n/a584
6215.074 x 47 x 41645003.60350002.4589

AHRI = Air-Conditioning, Heating & Refrigeration Institute

ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.

IEER = Integrated Energy Efficiency Ratio

SEER = Seasonal Energy Efficiency Ratio

COP = Coefficient of Performance

HSPF = Heating Seasonal Performance Factor

NOTES

1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate.


2. Ratings are based on:

» Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp.


3. 50FCQ units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes or visit the following website: http://bcap-energy.org

QTY