Carrier 40VMV 2-Pipe VRF Vertical Air Handling Unit 24k Btu/h Cooling

40VMV024---3
$0.00 / EACH
  • Availability: WarehouseAvailability::1051
  • Restricted: WarehouseRestricted::1001, WarehouseRestricted::1003, WarehouseRestricted::1005, WarehouseRestricted::1007, WarehouseRestricted::1009, WarehouseRestricted::1011, WarehouseRestricted::1013, WarehouseRestricted::1015, WarehouseRestricted::1017, WarehouseRestricted::1019, WarehouseRestricted::1021, WarehouseRestricted::1023, WarehouseRestricted::1025, WarehouseRestricted::1027, WarehouseRestricted::1029, WarehouseRestricted::1031, WarehouseRestricted::1033, WarehouseRestricted::1035, WarehouseRestricted::1037, WarehouseRestricted::1039, WarehouseRestricted::1041, WarehouseRestricted::1043, WarehouseRestricted::1045, WarehouseRestricted::1047, WarehouseRestricted::1049, WarehouseRestricted::1051, WarehouseRestricted::1053, WarehouseRestricted::1055, WarehouseRestricted::1057, WarehouseRestricted::1059, WarehouseRestricted::1061, WarehouseRestricted::1063, WarehouseRestricted::1065, WarehouseRestricted::1067, WarehouseRestricted::1069, WarehouseRestricted::1071, WarehouseRestricted::1073, WarehouseRestricted::1076, WarehouseRestricted::1077, WarehouseRestricted::1078, WarehouseRestricted::1079, WarehouseRestricted::1080, WarehouseRestricted::1105, WarehouseRestricted::1109, WarehouseRestricted::1111, WarehouseRestricted::1113, WarehouseRestricted::1114
  • : Each
  • : Pound(LB)
  • : Trading Goods (ZAW1)
  • : Carrier
  • : Technical Defect
  • : Standard Item (NORM)
  • Auto Enrichment Status: Ready
  • Blower Fan Max Esp: 0.8
  • Blower Motor Input: 1
  • Coil Fins Per Inch: 16°
  • Frequency: 60
  • Heating Capacity: 27000
  • Liquid Line Fitting: Scroll
  • Max Sound Level: 46.2
  • Blower Motor Type: Direct Current
  • Coil Number Of Circuits: Dark Bronze baked enamel finish
  • Condensate Pump: False
  • Liquid Line Size: 3/8
  • Mca: 3.8
  • Mid Sound Level: 42.3
  • Sensible Cooling Capacity: 17270
  • Coil Number Of Rows: Carrier
  • Metering Device Cooling: EEV
  • Min Sound Level: 37.9
  • Mopd: 15
  • Total Cooling Capacity: 24,000 (2.0 Tons)
  • Coil Tube Diameter: 69/250
  • Phase: Single
  • Suction Line Fitting: Scroll
  • Power Wiring: Sized per NEC and Local Codes based on Nameplate Electrical data
  • Suction Line Size: 5/8
  • Condensate Pipe Diameter: 3/4
  • Signal Wiring: 2-core stranded shielded cable 18AWG

Carrier VRF

Vertical Air Handling Unit

18,000 to 53,500 Btuh
1.5 to 4.5 Tons

The Carrier VRF Vertical Air Handling unit is a multi-positional unit - vertical and horizontal - ideal for closet applications.

Compatible Units & Controls

The 40VMV air handling unit is compatible with the 38VMR heat recovery, 38VMH heat pump and the 40VM9 remote controller.

Product Features

  • 208/230V-1-60Hz voltage
  • DC fan motor
  • Multiple fan speeds
  • Built-in IR receiver
  • Multi positional - vertical or horizontal

Reliability Features

  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL requirements
  • DC fan motor
  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant

Installation Features

  • Controls quick connects on all indoor units
  • All indoor unit settings can be done from the Remote Controller
  • Unit comes standard with IR receiver
QTY