Ductless - Outdoor unit, Heat Pump 25.0 38MAR 75.0, Single Zone

38MAQB09R--3
$0.00 / EACH
  • Restricted: WarehouseRestricted::1009, WarehouseRestricted::1057
  • : Each
  • : Carrier
  • : Obsolete
  • : Trading Goods (ZAW1)
  • : Technical Defect
  • Auto Enrichment Status: Done
  • Brand: Carrier
  • Equipment Type: Ductless Split System
  • Manufacturer: Carrier
  • Nominal Capacity (Ton): .75Ton
  • Product Line: Performance™
  • Refrigerant: R-410A
  • Seer: 25
  • Cfm: CLARCOR AIR FILTRATION PRODUCT
  • Coil Fins Per Inch: 18°
  • Compressor Model: ATM115D43UFZ2
  • Cooling Operating Range: -13~122
  • Eer: A/C Z INCS INC
  • Frequency: 60
  • Liquid Line Size: 1/4
  • Nominal Sound: 55.5
  • Phase: Single
  • Tonnage: 75+
  • Coil Number Of Circuits: Carrier
  • Compressor Type: Rotary Inverter
  • Cooling Capacity Max: 36460
  • Heating Operating Range: -22~86
  • Hspf: 1/2
  • Metering Device: EEV
  • Seer: 0.25
  • Coil Number Of Rows: Editor
  • Cooling Capacity Min: 10470
  • Mca: APPION INC
  • Refrigerant Weight: 3.31
  • Cop 17F: 292
  • Face Area: 4.51
  • Maximum Piping Length: 82
  • Cop 47F: 3/8
  • Minimum Circuit: APPION INC
  • Oil Charge: 17.6
  • Size: APPION INC
  • Suction Line Size: 3/8
  • Cop 5F: 212
  • Mocp Fuse Rating: 15
  • Oil Type: ESTER OIL VG74
  • Total Piping Length: 82
  • Heating Capacity Max: 11500
  • Piping Lift: 32°
  • Rated Current: 5.25
  • Heating Capacity Min: 4500
  • Heating Max Capacity 13F: 9020
  • Heating Max Capacity 17F: 9,000 (0.75 Tons)
  • Heating Max Capacity 5F: 9,000 (0.75 Tons)
  • Heating Rated Capacity 17F: 7200
  • Heating Rated Capacity 47F: 10900
  • Nominal Heating Capacity: 10900
  • Rated Cooling Capacity: 9,000 (0.75 Tons)
Overview

Designed for versatility and year-round comfort, the 38MAR achieves full heating capacity even as temperatures outside dip to 5° F (with the right combination of model size and matched indoor unit). This quiet, compact heat pump pairs with a variety of indoor units for a budget-friendly and flexible solution to your duct-challenged comfort needs. Part of our Performance Series, this model really delivers with features like variable speed operation for extra efficiency and reduced sound.


Features

STANDARD FEATURES

  • 100% Heating Capacity at 5° F (-15° C)*
  • Inverter Compressor
  • Up to 25.0 SEER cooling efficiency
  • Up to 12.0 HSPF heating efficiency
  • Available in 115V and 208/230V
  • Built-in basepan heater
  • Piping length 82 ~ 164 ft. (25 ~ 50 m) depending on unit capacity
  • Refrigerant leakage detection
  • Condenser high-temperature protection
  • Quiet outdoor sound operation, as low as 52.5 decibels1
  • 10-year parts limited and 10-year compressor limited warranties to the original purchasing owner upon timely registration2


Quietest size within each model group during most common cooling operating condition.

If properly registered within ninety (90) days after original installation, parts are warranted to the original purchaser for a period of 10 years. Otherwise, parts warranty is 5 years. For other applications a 7-year parts and 7-year compressor limited warranties apply. See warranty certificate for details.

* Sizes 9-24 (208/230V). Dependent upon indoor unit combination.

Specifications

EFFICIENCY

  • Up to 25.0 SEER
  • Up to 15.0 EER
  • Up to 12.0 HSPF
  • Select sizes are ENERGY STAR® certified based on indoor unit pairing 

PERFORMANCE

  • Outdoor sound: as low as 52.5 decibels1

OUTDOOR OPERATING RANGE

  • Cooling mode Min-Max DB: Range is -13° ~ 122°F (-25° ~ 50°C)
  • Heating mode Min-Max DB: Range is 22° ~ 86°F (-30° ~ 30°C) - Sizes 9-24 (208/230V) -13° ~ 86°F (-25° ~ 30°C) – Sizes 9, 12 (115V) & 30, 36 (208/230V)

LINE LENGTH

  • Up to 164 ft. (50 m)

TECHNOLOGY

  • Inverter Compressor

CAPACITIES

  • 0.75 - 3 tons 

REQUIREMENTS

  • 1 ton 115V 
  • 0.75 - 3 tons 208/230V

AESTHETICS

  • Heavy-gauge, galvanized steel construction
  • Primed and coated with a 100% coverage, baked-enamel finish in white
COMPARE TO OTHER MODELS

1 Quietest size within each model group during most common cooling operating condition.