Gas Heat/Electric 10 Ton Packaged Rooftop Unit

48TCDD12A2A6-0A0G0
$0.00 / EACH
  • : Trading Goods (ZAW1)
  • : 03 - Use
  • : Each
  • : Pound(LB)
  • : Standard Item (NORM)
  • Auto Enrichment Status: Ready
  • Airflow: 5000
  • Alternate(Humidimizer) Charge A: 16-10
  • Charge(A): 10-5
  • Coil Type: RTPF
  • Coil Type: RTPF
  • Connection Size: 3/4-in. NPT
  • Connection Size: 3/4-in. NPT
  • Fan Diameter: 22
  • Fan Diameter: 15 x 15
  • First Stage: 0.14
  • Fla: 0.8
  • Oa Inlet Screen Quantity: 1
  • Alternate(Humidimizer) Charge B: 16-0
  • Alternate(Mchx) Charge B: 6-0
  • Certifications: AHRI
  • Condensate Drain Connection Size: 3/4
  • Fan Quantity: 1
  • Fpi: 17
  • Liquid Propane Supply Line Pressure Psig: 0.040-0.047
  • Lra: BERRY PLASTICS
  • Motor Drive Type: Direct
  • Number Of Burners: 4"
  • Number Of Burners: 4"
  • Oa Inlet Screen Size: 20 x 24 x 1
  • Second Stage: 0.14
  • Coil Type: Novation
  • Coil Type: RTPF
  • Compressor Capacity Staging: 50% / 100%
  • Compressor Type: Scroll
  • Cooling Capacity: 114
  • Fan Type: Centrifugal
  • Fpi: 15
  • Motor Hp: 1/4
  • Number Of Stages: 2
  • Number Of Stages: 2
  • Ra Filter Quantity: 4"
  • Rla: 7.7
  • Rows: 2
  • Eer: 11
  • Fpi: 17
  • Fpi: 20"
  • High Pressure Reset: 505
  • Max Bhp: 3.7
  • Motor Quantity: 2
  • Natural Gas Supply Line Pressure Psig: 0.18-0.47
  • Ra Filter Size: 20 x 20 x 2
  • Rollout Switch Closes: 115
  • Rollout Switch Closes: 115
  • Rows: 4"
  • Total Face Area: 25.1
  • Efficiency: 82
  • Fuse Amps: 25'
  • High Pressure Trip: 630
  • Metering Device(Humidimizer): Accutrol + TXV
  • Motor Drive Type: Belt
  • Motor Rpm: 1100
  • Number Of Gas Valves: 1
  • Rollout Switch Opens: 195
  • Rollout Switch Opens: 195
  • Rows: 1
  • Total Face Area: 11.1
  • Tube Diameter: 3/8
  • Heating Capacity: 148
  • Low Pressure Reset: 117
  • Motor Frame Size: 56
  • Rows: 2
  • Temperature Rise Maximum: BACHRACH INC
  • Temperature Rise Maximum: BACHRACH INC
  • Total Face Area: 25.1
  • Tube Diameter: 3/8
  • Tube Material/Fin Material: Cu/Al
  • Ieer: 12.8
  • Low Pressure Trip: 50-54
  • Motor Quantity: 1
  • Temperature Rise Minimum: 20"
  • Temperature Rise Minimum: 25'
  • Total Face Area: 8.4
  • Tube Material/Fin Material: Cu/Al
  • Tube Material/Fin Material: Al/Al
  • Metering Device: Accutrol
  • Minimum Circuit: 22
  • Rpm Maximum: 1084
  • Tube Diameter: 3/8
  • Number Of Circuit: 2
  • Rpm Minimum: 838
  • Sound Level: 82
  • Tube Material/Fin Material: Cu/Al
  • Number Of Compressor: 2
  • Total Power: 10.3
  • Refrigerant Type: R-410A

Gas Heating / Electric Cooling with Puron® (R-410A) Refrigerant

6 to 27.5 Nominal Tons

48TC WeatherMaker® rooftop units were designed by customers for customers. With a gauge plug, centralized control center, plug & play accessory board, “no-strip screw” collars, and handled access panels, we’ve made the unit easy to install, easy to maintain, and easy to use. Units are pre-wired and pre-charged with environmentally sound Puron® (R-410A) refrigerant at the factory. The units are factory tested in both heating and cooling modes.

Features

Performance Features

  • ASHRAE 90.1 compliant
  • Up to 13.0 SEER, 11.8 IEER, and 11.1 EER
  • Gas efficiencies up to 82%
  • Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit
  • Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Exclusive IGC solid-state control for on-board diagnostics with LED error code designation, burner control logic and energy saving indoor fan motor delay
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Maintenance Features

  • Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Optional hinged access panels also available
  • Belt drive evaporator-fan motor and pulley combinations available to meet any application
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time
  • Field convertible from vertical to horizontal airflow for slab mounting (sizes 04-16)
  • Provisions for thru-the-bottom power entry capability as standard
  • Dedicated vertical and horizontal airflow models available (sizes 17 to 30 only)
  • Single point gas, electric, and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Exclusive IGC anti-cycle protection for gas heat operation
  • Solid-state electronic direct spark ignition system and flame roll-out safety protector

Standard Limited Warranty

  • 10 years parts only heat exchanger - aluminized
  • 15 years parts only heat exchanger - stainless steel
  • 5 years parts only compressor
  • 3 years parts only on Novation™ condenser coil
  • One year parts only on all other parts
  • Extended warranty packages available
Options

Factory-Installed Options

  • Cabinet
    • Thru-the-base electrical or gas-line connections
    • Hinged access panels
  • Coil Options
    • Cu/Cu indoor and/or outdoor coils
    • Pre-coated outdoor coils
    • Premium, E-coated outdoor coils
  • Humidity Control
    • Humidi-MiZer Adaptive dehumidification system (sizes 04-28 only)
  • Condenser Protection
    • Condenser coil hail guard (louvered design)
  • Controls
    • PremierLink DDC communicating controller
    • RTU OPEN multi-protocol controller
    • Smoke detector (supply and/or return air)
  • Economizers & Outdoor Air Dampers
    • EconoMi$er IV (for electro-mechanical controlled RTUs)
    • EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)
    • EconoMi$er2 (for DDC controlled RTUs)
    • Ultra-low leak economizer dampers
    • Motorized 2 position outdoor-air damper
    • Manual outdoor-air damper (sizes 17-30)
    • Barometric relief
    • Power exhaust (sizes 17-30)
  • Economizer Sensors & IAQ Devices
    • Single dry bulb temperature sensors
    • Single enthalpy sensors
    • CO2 sensor (wall, duct, or unit mounted)
  • Indoor Motor & Drive
    • Multiple motor and drive packages
    • Staged Air Volume (SAV) Indoor Fan Speed System (sizes 08-30)
  • Power Options
    • Convenience outlet (powered)
    • Convenience outlet (unpowered)
    • Non-fused disconnect

Field-Installed Accessories

  • Cabinet
    • Thru-the-base electrical or gas-line connections
  • Condenser Protection
    • Condenser coil hail guard (louvered design)
  • Controls
    • Thermostats, temperature sensors, and subbases
    • PremierLink DDC communicating controller
    • RTU OPEN multi-protocol controller
    • Smoke detector (supply and/or return air)(sizes 17-30)
    • Time Guard II compressor delay control circuit
    • Filter status switch
    • Fan status switch
  • Economizers & Outdoor Air Dampers
    • EconoMi$er IV (for electro-mechanical controlled RTUs)
    • EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)
    • EconoMi$er2 (for DDC controlled RTUs)
    • Ultra-low leak economizer dampers
    • Motorized 2 position outdoor-air damper
    • Manual outdoor-air damper (sizes 17-30)
    • Barometric relief
    • Power exhaust(sizes 17-30)
  • Economizer Sensors & IAQ Devices
    • Single dry bulb temperature sensors
    • Differential dry bulb temperature sensors
    • Single enthalpy sensors
    • Differential enthalpy sensors
    • CO2 sensor (wall, duct, or unit mounted)
  • Gas Heat
    • Liquid propane (LP) conversion kit
    • High altitude conversion kit
  • Low Ambient Control
    • Winter start kit
    • Motormaster head pressure controller
  • Roof Curbs
    • Roof curb 14" (356mm)
    • Roof curb 24" (610mm)
Physical Data
Nominal Cooling Ton SizeCooling StagesAHRI Efficiency (SEER) EERDimensions (in) LxWxHLow Gas Heating Input (MBtuh)Medium Gas Heating Input (MBtuh)High Gas Heating Input (MBtuh)Approx. Unit Weight (lbs)
6111.074 x 47 x 4172125150652
7.5111.088 x 59 x 41125180224780
7.5211.088 x 59 x 41125180224835
8.5111.088 x 59 x 49125180224920
8.5211.088 x 59 x 49125180224930
10111.088 x 59 x 49180224250930
10211.188 x 59 x 49180224250940
12.5210.888 x 59 x 491501802401167
15210.8116 x 63 x 572203104001380
15210.8128 x 87 x 492203104001907
17.5210.8128 x 87 x 492203104001922
2029.8141 x 87 x 492203104002072
2529.8141 x 87 x 492203104002197
27.5210.2158 x 87 x 572203104002320

AHRI = Air-Conditioning, Heating & Refrigeration Institute

ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.

EER = Energy Efficiency Ratio

SEER = Seasonal Energy Efficiency Ratio

NOTES

1. Rated and certified under ARI Standard 210/240---06 or 340/360---07, as appropriate.


2. Ratings are based on:

» Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp.


3. All 48TC units comply with ASHRAE 90.1-2010 Energy Standard for minimum SEER and EER requirements.


4. 48TC units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes or visit the following website: http://bcap-energy.org

QTY